- Accuracy class of 1% F.S. Knife edge pointer Moving coil type Panel mount 0° to 90° deflection and linear operation Operating voltage of 110V/ 220V/ 440V Power Consumption is <2VA.
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1% F.S. Knife edge pointer Moving coil type Panel mount 0° to 90° deflection and linear operation Operating voltage of 110V/ 220V/ 440V Power Consumption is <2VA.
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S Knife edge pointer Moving iron type Panel mount 0° to 90° deflection Non linear operation Overload Capacity of 1.2 times of Rated current and has up to 10 times of rated current for max of 5 sec Power Consumption is 0.8VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S Knife edge pointer Moving iron type Panel mount 0° to 90° deflection Non linear operation Overload Capacity of 1.2 times of Rated current and has up to 10 times of rated current for max of 5 sec Power Consumption is 0.8VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S Knife edge pointer Moving coil type Panel mount 0° to 90° deflection Non linear operation Direct measurement of current up to 100A without connecting any external CT Overload Capacity of 1.2 times of Rated current and has up to 10 times of rated current for max of 5 sec Power Consumption is 0.8VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S Knife edge pointer Moving coil type Panel mount 0° to 90° deflection Non linear operation Direct measurement of current up to 100A without connecting any external CT Overload Capacity of 1.2 times of Rated current and has up to 10 times of rated current for max of 5 sec Power Consumption is 0.8VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S. Knife edge pointer Moving coil type Panel mount 45° -0°- 45° deflection and non linear operation Operating voltage of 415 & 440V Power Consumption is 0.8VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S. Knife edge pointer Moving coil type Panel mount 45° -0°- 45° deflection and non linear operation Operating voltage of 415 & 440V Power Consumption is 0.8VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S. Knife edge pointer Moving iron type 0° to 90° deflection and non linear operation Measurement of voltage between 0 to 300V/500V Overload Capacity up to 2 times of rated voltage for max of 5 sec Power Consumption of 4.5VA
- Read more
-
-
- Analog Panel Meters
-
- Accuracy class of 1.5% of F.S. Knife edge pointer Moving iron type 0° to 90° deflection and non linear operation Measurement of voltage between 0 to 300V/500V Overload Capacity up to 2 times of rated voltage for max of 5 sec Power Consumption of 4.5VA